IPC-7530 Guidelines for Temperature Profiling for Mass Soldering Processes (Reflow & Wave) ASSOCIATION CONNECTING ELECTRONICS INDUSTRIES® 2215 Sanders Road, Northbrook, IL. GFM2-OILT-02 2-1/16' Freedom CAN-BUS Oil Temp Gauge 60-150C Metric (For GM vehicles only). WTP35/WTP65 Precision Sea Water Temp. Gauge (w/o temperature transducer) WTP35/WTP65 precision sea water temperature gauge with digital display to 0.1 deg F or 0.1 deg C. With a range of 32.0 deg F (0.0 deg C) to 90.0 deg F (32.2 deg C). Click for details. T35 / T65 Multi-Zone Digital Temperature Monitor (w/o temp.
The Pro-Gauges controller makes it possible to interface your computer with a wide range of real car instruments, through the USB port.
At the moment the list of supported instruments is:
- Rev counter
- Electronic speedometer
- Fuel level gauge
- Water temperature gauge
- Fuel pressure (electronic) gauge
- Oil temperature gauge
- Oil pressure (electronic) gauge
- Turbo pressure gauge
- Brakes' air pressure
Configuring the rev counter
The pomodoro technique is designed to help.
- Enable the Pro-Gauge output that will drives the rev counter, clicking the checkbox marked with 1 in the picture above.
- In the section marked with 5, set the maximum value of RPM for your specific rev counter.
- There are 21 sliders in the Rev Counter configuration screen. Each slider has to be adjusted until the needle of the rev counter indicates the value displayed on the TEST button, between brackets). For example, in the picture above, the slider marked with 3 has to adjusted until the rev counter display the value 1.000 RPM. For fine tuning, the UP and DOWN arrows of the numeric textbox marked with 2 can be used.
Configuring the speedometer
The configuration section for the speedometer is in the picture above and is very similar to the one for the rev counter. Each slider has to be adjusted until the speedometer displays the speed value shown on the TEST button, at the right of the slider.
In the picture above for example, the slider marked with 3 must to be moved until speedometer displays the speed 30 Km/h.
The section marked with 5 indicates the speedometer's maximum speed value.
The signal wire from the speedometer connects to the controller's terminal marked with SPD. The 12V and ground wires connect to the 12V and GND terminals of the Pro-Gauge.
Configuring the other gauges
The gauges indicating water and oil temperature, fuel level and pressure and oil pressure must be configured in the section displayed ain the picture above.
There are 5 sliders and each one has to be adjusted until the needle of the gauge moves to 0%, 25%, 50%, 75% and 100% of the range. Neat download manager 1 1.
The section marked with 5 in the picture above is used to set what type of data is displayed by the gauge, the unit the data is displayed in and the minim and maximum values of the gauge.
For each of the S1…S6 connectors there is a jumper on the board that can be moved to 6 different positions (see picture above). POSITION 1 is the default position and should be tried first when adjusting the 5 sliders in the gauges configuration screen.
If any of the following situations happens:
- the needle of the gauge doesn't move
- the needle of the gauge doesn't reach the MIN or the MAX values of the gauge
- it is not possible to set the needle position accurately because to a small movement of the sliders in the configuration screen, corresponds a big movement of the needle
In any of these cases, move the jumper from POSITION 1 to POSITION 2 and try to configure the gauge again. If the same problem happens again, move the jumper to the next position and so on until you have tried all 6 jumper positions.
The higher the jumper position the more accurately the needle can be positioned. On the other hand when the jumper position is increased, the range of the signal sent to the gauge is reduced, so it is a matter of finding the right balance between signal range and accuracy.
If after you have tried to move the jumper to all 6 possible positions you still can't configure the gauge, have a look at the section below that talks about the Signal Adapter.
The signal wire from the gauge connects to the S1…S6 terminals of the controller (one of them). the 12V and ground wires from the gauge connect to the 12V and GND terminals.
Signal adapter
Temperature Gauge Pro 2 9 5 Download Free Mac
The signal adapter should be used if the needle of the gauge doesn't reach the MIN or the MAX positions of the gauges, when you move the sliders in the configuration screen.
Move the jumper on the Pro-Gauge board to a position where you are able to move the needle of the gauge, when you adjust the sliders in the configuration screen. It is ok if the needle doesn't reach the MAX position of the gauge.Choose a position for the jumper as low as possible. So if both positions 1 and 2 make the needle move, prefer position 1. Move the needle to the maximum position you are able to. Don't push the slider all the way to the right but stop when the needle can't move any higher.
Connect the signal adapter to the gauge (see instructions below) and adjust the blue potentiometer using a screwdriver. The process is a bit trial and error but when you adjust the potentiometer at some point the needle of the gauge should start moving. Keep adjusting the potentiometer until the needle reaches the gauge's MAX position.
Go back to the Pro-Gauge configuration screen and adjust the sliders. If now you are able to move the gauge's needle all the way from the MIN to the MAX positions, you are done, otherwise you will have to keep playing with the potentiometer and possible with the position of the blue jumper on the Pro-Gauge.
The potentiometer of the signal adapter can be turned 15 times to the left or to the right. When you reach the start or the end positions the screw doesn't block but you should be able to hear a click, from the potentiometer. That means you have turned it all the way, and keeping turning it doesn't produce any effect.
The signal adapter has 4 connections:
- - The GND terminal connect to the GND of the Pro-Gauge and the ground wire of the gauge (usually black)
- - The 12V terminal connects to the 12V terminal of the Pro-Gauge and the 12V wires of the gauge
- - The S terminal connects to one of the terminals S1…S6 of the Pro-Gauge
- - The G terminal connects to the gauge's signal wire.
- the needle of the gauge doesn't move
- the needle of the gauge doesn't reach the MIN or the MAX values of the gauge
- it is not possible to set the needle position accurately because to a small movement of the sliders in the configuration screen, corresponds a big movement of the needle
In any of these cases, move the jumper from POSITION 1 to POSITION 2 and try to configure the gauge again. If the same problem happens again, move the jumper to the next position and so on until you have tried all 6 jumper positions.
The higher the jumper position the more accurately the needle can be positioned. On the other hand when the jumper position is increased, the range of the signal sent to the gauge is reduced, so it is a matter of finding the right balance between signal range and accuracy.
If after you have tried to move the jumper to all 6 possible positions you still can't configure the gauge, have a look at the section below that talks about the Signal Adapter.
The signal wire from the gauge connects to the S1…S6 terminals of the controller (one of them). the 12V and ground wires from the gauge connect to the 12V and GND terminals.
Signal adapter
Temperature Gauge Pro 2 9 5 Download Free Mac
The signal adapter should be used if the needle of the gauge doesn't reach the MIN or the MAX positions of the gauges, when you move the sliders in the configuration screen.
Move the jumper on the Pro-Gauge board to a position where you are able to move the needle of the gauge, when you adjust the sliders in the configuration screen. It is ok if the needle doesn't reach the MAX position of the gauge.Choose a position for the jumper as low as possible. So if both positions 1 and 2 make the needle move, prefer position 1. Move the needle to the maximum position you are able to. Don't push the slider all the way to the right but stop when the needle can't move any higher.
Connect the signal adapter to the gauge (see instructions below) and adjust the blue potentiometer using a screwdriver. The process is a bit trial and error but when you adjust the potentiometer at some point the needle of the gauge should start moving. Keep adjusting the potentiometer until the needle reaches the gauge's MAX position.
Go back to the Pro-Gauge configuration screen and adjust the sliders. If now you are able to move the gauge's needle all the way from the MIN to the MAX positions, you are done, otherwise you will have to keep playing with the potentiometer and possible with the position of the blue jumper on the Pro-Gauge.
The potentiometer of the signal adapter can be turned 15 times to the left or to the right. When you reach the start or the end positions the screw doesn't block but you should be able to hear a click, from the potentiometer. That means you have turned it all the way, and keeping turning it doesn't produce any effect.
The signal adapter has 4 connections:
- - The GND terminal connect to the GND of the Pro-Gauge and the ground wire of the gauge (usually black)
- - The 12V terminal connects to the 12V terminal of the Pro-Gauge and the 12V wires of the gauge
- - The S terminal connects to one of the terminals S1…S6 of the Pro-Gauge
- - The G terminal connects to the gauge's signal wire.
One signal adapter is included with the Pro-Gauge but more can be purchased separately if needed.
Please note: the Pro-Gauge might not work correctly with tachometers designed for trucks. Typically these tachometers reach the end of the scale at 3.000 or 4.000 RPM
- Product Code: Pro-Gauge
£59.50
Available Options
Related Products
Signal Adapter
The signal adapter is a small board that is used to make the Pro-Gauge controller compatible with a .
Aol 9.5 Download
£3.50
Relay module for Pro-Gauge
The Relay Module for the Pro-Gauge controller can be used to automatically switched on and off the g.
£5.00
80mm High Speed stepper motor Tachometer 11000 RPM
This tachometer offers extremely fast movements. The main features are:It uses high precision .
£69.50
As one of our core offerings, Temp-Pro designs and manufactures temperature sensor products to include Thermocouples, resistance temperature devices (RTDs), thermistors, and associated components and hardware. Our precision-engineered temperature sensors are built for accuracy, versatility and durability in the most demanding industrial environments.
Temp-Pro's expertise, knowledge and insight are also geared to provide responsive solutions for prototype programs to ensure customer success. We also collaborate with our sensor engineering expertise to support a variety of innovative or 'reverse' engineering applications related to temperature sensors. Whether you need temperature sensors for voltage regulation, time-based applications, or circuit protection, Temp-Pro is ready to support your engineering needs.
- Type 011 – Spring Loaded RTDs
- Type 011 – Spring Loaded Thermocouples
- Type 02 – Fixed Insertion/Direct Mounting RTDs
- Type 02 – Fixed Insertion/Direct Mounting Thermocouples
- Type 03 – Oil Tight Removable Sensor RTDs
- Type 03 – Oil Tight Removable Sensor Thermocouples
- Type 04 – Bearing RTDs
- Type 04 – Bearing Thermocouples
- Type 05 – Standard Industrial Thermocouples
- Type 06 – RTD Sensors with Plug Connection
- Type 06 – Thermocouple Sensors with Plug Connection
- Type 07 – RTD Sensors with Small Terminal Head
- Type 07 – Thermocouple Sensors with Small Terminal Head
- Type 09 – Spring Loaded Pipe Clamp Assembly RTDs
- Type 09 – Spring Loaded Pipe Clamp Assembly Thermocouples
- Type 11 – RTDs with Extension Wires
- Type 11 – Thermocouples with Extension Wires
- Type 12 – Thermocouples – Stick Probe
- Type 13 – -165 to 250°C RTDs
- Type 14 -250 to 550°C RTDs
- Type 19 – 24 Gauge Alumina Insulated Noble Metal High Temperature Thermocouples
- Type 31 – Multipoint Thermocouple Temperature Sensors – Flexible Strip
- Type 32 – Multipoint RTD Temperature Sensors – Bundle Sensor Unit
- Type 32 – Multipoint Thermocouple Temperature Sensors – Bundle Sensor Unit
- Type 33 – Multipoint RTD Temperature Sensors – Springloaded Bundle
- Type 33 – Multipoint Thermocouple Temperature Sensors – Springloaded Bundle
- Type 34 – Multipoint RTD Temperature Sensors – Guide Tube Unit
- Type 34 – Multipoint Thermocouple Temperature Sensors – Guide Tube Unit
- Type 83 – Bimetal Thermometers
Through our depth of knowledge and resources, Temp-Pro provides a 'best-value' option for the production of both prototype and build-to-print temperature sensor designs—whether in large or small quantities. And since 1972, our temperature sensor design and production capacity has supported the most demanding needs of OEM industry and operating facilities around the world.
And don't forget that Temp-Pro's ISO 9001:2015 certification ensures that we maintain the highest quality standards to ensure your satisfaction throughout every stage of our business relationship. With more than four decades of experience, our company has a strong culture of customer satisfaction that has become our trademark value.
Phone: (413) 584-3165
Toll Free: 800-991-9093
Fax: 413-586-3625
Email: sales@temp-pro.com